Troubleshooting
The table below lists the possible causes and any corrective actions required for
conditions that may occur with your machine. For conditions not covered below, contact
your Pressure Seal Systems distributor.
Condition Possible Cause Corrective Action
The power-on indicator
does not light.
Mains lead not plugged into
an AC outlet.
Plug mains lead into an AC
outlet.
Mains plug fuse blown. Replace fuse. If the
replacement fuse blows,
contact your Pressure Seal
distributor for advice.
Board fuse blown. Contact your Pressure Seal
distributor for advice.
The machine does not
operate when the On/Start
button is pressed (power
on)
Form misfeed, jam detected:
error message displayed.
Clear mishandled forms.
No forms loaded. Load forms.
Board fuse blown. Contact your Pressure Seal
distributor for advice.
Forms are mishandled in the
folder or damaged during
sealing.
Fold plate form stop(s)
adjusted improperly.
Check and adjust the
position of the fold plate
form stop(s). See page 16.
Debris in folding plates;
folding plates not installed
properly; fold plate form
stop(s) adjusted improperly.
Remove debris; properly
install fold plates; check
position of the fold plate
form stop(s).
5. Operation Errors PS 600
Page 36 22-01-03 Iss. B.